Three-Phase DC/AC Total Box Panel TBTF 2/2 1000V

Total Box TBTF 2/2 1000V: a combined enclosure integrating both DC-side and AC-side protection of a three-phase PV system with two independent strings up to 1000 Vdc. Includes 1000V load-break isolator, Type 2 SPD 1000V, 1000V 32A fuse holder with gPV fuses, three-phase RCBO 25A 300mA type A, a production-meter in/out switch and a 400V SPD. IP65 enclosure, 36 DIN modules, compliant with CEI 0-21, CEI EN 61439 and CEI 64-8.

€659.19 Tax escl.

The Icierre Total Box TBTF 2/2 1000V is a combined switchboard bringing together, in a single unit, every protection a three-phase PV system with two independent strings up to 1000 Vdc requires: it safely manages both the PV module strings (DC side) and the three-phase grid connection (AC side), and also integrates the in/out switch for the production meter.

Why do you need a two-string three-phase Total Box?

Every PV system must be protected against overcurrent, surges and insulation faults, and must be safely isolated for maintenance. With two independent strings, each input needs separate protection and isolation, while the three-phase side needs a four-pole residual current circuit breaker and a 400V surge arrester. The Total Box TBTF 2/2 1000V integrates all these devices into one certified enclosure, compliant with CEI 0-21, CEI EN 61439 and CEI 64-8.

TBTF 2/2 1000V technical specifications

ConfigurationThree-phase — 2 IN / 2 OUT
Max DC voltage1000 Vdc
Number of strings2 independent strings
DC isolation1000V 16/32A load-break isolator
DC protectionType 2 SPD 1000V + 1000V 32A fuse holder with 16/20A gPV fuses
AC protectionThree-phase RCBO 25A, 300mA type A
Production meter1 in/out switch provided
AC-side SPD400V Type 2 surge arrester
ConnectionsPre-wired input/output terminal blocks
EnclosureIP65 box, 36 DIN modules, component identification labels on plasticised rails
StandardsCEI 0-21, CEI EN 61439, CEI 64-8

When is the TBTF 2/2 1000V the right choice?

It suits three-phase PV systems with two independent strings and open-circuit voltage up to 1000 Vdc, typically installations of around 10-15 kWp with a dual-MPPT three-phase inverter, or arrays split across roof pitches with different orientations. For a single string choose the TBTF 1/1 1000V; for single-phase systems, the TBMF family.

What is included

  • Total Box TBTF 2/2 1000V in an IP65 36-module enclosure, pre-wired and certified
  • 1000V load-break isolator, Type 2 SPD 1000V and fuse holder with gPV fuses on the DC side
  • Three-phase 25A RCBO and 400V Type 2 SPD on the AC side
  • In/out switch for connecting the production meter
  • Input/output terminal blocks and component identification labels on plasticised rails

Frequently asked questions

What is the production-meter in/out switch for?

It allows the production meter to be inserted into the AC line without adding a separate board: the line runs into the meter and back out towards the connection point. This is useful where generated-energy metering is required by the network operator or an incentive scheme, and it also makes bypassing the meter for maintenance straightforward.

What is the difference between the TBTF 2/2 1000V and the TBTF 1/1 1000V?

The 2/2 handles two independent strings instead of one, with separate protection and isolation per input, and carries a 25A three-phase RCBO instead of 16/20A, plus the in/out switch for the production meter. It therefore covers larger systems.

Is the TBTF 2/2 1000V pre-wired or do I have to assemble it?

It arrives pre-wired and certified: isolator, SPD, fuse holders and three-phase RCBO are mounted and connected to the input and output terminal blocks. You only need to fix it to the wall and connect the PV strings and the three-phase line.

What system size does this board cover?

With two strings at 1000 Vdc and a 25A three-phase AC breaker, the TBTF 2/2 1000V typically covers systems up to around 15 kWp with a dual-MPPT three-phase inverter. Sizing should always be checked against the rated current of the inverter actually installed.

Which documents are needed for the grid connection application?

The distribution network operator requires a single-line diagram, a declaration of conformity and the rating data of the installed protective devices. Being a certified board with labelled components, the Total Box simplifies preparing this documentation.