X3-HYB-6.0-P
SolaX X3-HYB-6.0-P 6 kW three-phase hybrid inverter from the X3-HYB G4 PRO range, for solar PV with compatible high-voltage storage. IP66 enclosure, EPS backup and CEI 0-21 listed in the manufacturer datasheet; CT included in the MR WATT catalogue supply.
The SolaX X3-HYB-6.0-P is a 6 kW three-phase hybrid inverter in the G4 PRO range. It converts solar power and manages energy exchange with compatible batteries for systems combining self-consumption, storage and a properly designed EPS backup circuit.
Why choose a three-phase hybrid inverter?
Storage lets you use some of the available solar energy later. The 6 kW AC rating must be matched to the solar array, loads and battery; it is not a guaranteed daily energy yield.
Technical specifications X3-HYB-6.0-P
| Rated AC power | 6 kW |
| Maximum recommended PV array power | 12 kWp, with strings kept within electrical limits |
| Grid | Three-phase, 230/400 V |
| Maximum PV voltage | 1000 V |
| MPPT range | 110–950 V |
| Battery | Compatible lithium, 130–800 V |
| Maximum efficiency | 98.0% |
| Enclosure protection | IP66 |
| EPS changeover | Under 10 ms |
| Dimensions W × H × D | 560 × 503 × 210 mm |
| Net weight | 38 kg |
| Manufacturer references | CEI 0-21, EN 50549, IEC 62109-1/-2 |
Installation and compatibility
The installer must check string voltages, input currents, BMS compatibility and local grid connection requirements. The datasheet lists CEI 0-21; certificates for the exact model and firmware must be checked for the relevant application. Backup requires a compatible battery and dedicated EPS wiring.
What is supplied?
- SolaX X3-HYB-6.0-P G4 PRO inverter.
- CT current transformers listed as included in the MR WATT product record.
- Batteries, external protection and installation accessories must be specified in the system design and order.
How long could a battery power my loads?
Calculation example, not a yield forecast: 10 kWh of usable energy at a constant 1 kW load gives 10 theoretical hours before losses. Actual runtime depends on loads, battery reserve and system limits. The inverter power rating does not include a battery.
Frequently asked questions
Does a 6 kW inverter generate 6 kWh every hour?
No. 6 kW is the inverter's rated AC power. Available energy depends on the panels, sunlight and battery; a constant output of 1 kW for 4 hours equals 4 kWh.
Can the SolaX X3-HYB-6.0-P power my home during a blackout?
EPS can supply loads connected to the backup circuit when a compatible battery and correct configuration are in place. It does not automatically back up the whole house; load power and starting surges must be checked.
Which batteries can I connect?
The datasheet specifies compatible lithium batteries in the 130–800 V range. Check the SolaX compatibility list, BMS, firmware and module configuration before ordering; a matching voltage alone is insufficient.
Can I use it on a single-phase supply?
This is a three-phase inverter. Connection, load distribution and protection must be designed for a three-phase grid; it is not a direct replacement for a single-phase inverter.
Are CTs, batteries and documents included?
The MR WATT supply record includes CTs. Batteries and system accessories must be specified in the order. The installer must obtain the manual, relevant certificates and system diagram.