Why solar panels produce less when it is hot
Temperature coefficient, NOCT and ventilation explained with PVGIS data: how much is lost in summer, why it happens and what you can do about it.
July is almost always the month with the most kWh, yet in that month every ray of sunlight is converted less efficiently than in January. The reason is cell temperature. Understanding it helps you choose the right module, install it properly and not be surprised when the inverter shows less than the nameplate power.
−8 %
yearly temperature loss of a well-ventilated system in Rome (PVGIS)
−0.25…−0.35 %/°C
typical temperature coefficient of silicon modules
66 °C
cell temperature in full sun with 35 °C air
The summer paradox: more energy, less efficiencyCell temperature: STC and NOCTThe temperature coefficient: how much is lost per degreeVentilation matters as much as the moduleWhat to do in practiceProducts to choose wellFAQ and further reading
01The summer paradox: more energy, less efficiency
A system's output depends mainly on how much light reaches the modules, and in summer much more of it does. The ratio between energy produced and light received, called the performance ratio (PR), tells another story: it drops precisely in the hottest months.
| Month | kWh produced | Efficiency (PR) |
|---|---|---|
| January | 84 | 83 % |
| February | 97 | 82 % |
| March | 125 | 80 % |
| April | 138 | 78 % |
| May | 149 | 77 % |
| June | 155 | 74 % |
| July | 168 | 73 % |
| August | 159 | 74 % |
| September | 133 | 76 % |
| October | 113 | 79 % |
| November | 83 | 81 % |
| December | 79 | 83 % |
1 kWp system in Rome, modules tilted at 30° facing south, free-standing (well ventilated). PVGIS 5.3, 14% system losses. Yearly total about 1,484 kWh, average PR 77%. Rounded values.
In July the system produces twice as much as in December, but converts light with an efficiency about 10 points lower. Over the whole year PVGIS estimates that temperature and irradiance cost a well-ventilated system about 8% of its energy.
02Cell temperature: STC and NOCT
A module's nameplate power is measured under standard test conditions (STC): 1,000 W/m² irradiance and cells at 25 °C. On a roof in full sun the cells are never at 25 °C: they heat up 20-35 °C above the air temperature.
To estimate this you use the NOCT (or NMOT) from the datasheet: the temperature the cells reach at 800 W/m², 20 °C air and a light breeze. Modern modules usually sit at 41-45 °C.
With poorly ventilated modules, laid on metal sheeting or integrated into the roof, the temperature can exceed 75 °C.
03The temperature coefficient: how much is lost per degree
The temperature coefficient of power (Pmax) tells you how much power the module loses for every degree above 25 °C. It is one of the most useful numbers on the datasheet, and it depends on the cell technology.
| Technology | Pmax coeff. | Loss at 66 °C | 450 W become |
|---|---|---|---|
| PERC | −0.35 %/°C | ≈ −14 % | ≈ 385 W |
| TOPCon | −0.30 %/°C | ≈ −12 % | ≈ 395 W |
| Back contact | −0.29 %/°C | ≈ −12 % | ≈ 396 W |
| Heterojunction (HJT) | −0.25 %/°C | ≈ −10 % | ≈ 404 W |
Typical datasheet values: always check those of the module you are considering. The loss is calculated for 41 °C above STC, before other system losses.
The loss is reversible: when the cell cools down, the power comes back. But in the hottest hours a module with a better coefficient can deliver 15-20 W more per 450 W, and over 25 years the difference adds up.
In the cold the opposite happens: open-circuit voltage (Voc) rises by about 0.25-0.30% for every degree below 25 °C. With cells at −10 °C a 41 V module reaches about 45 V, and a string of 10 modules goes from 410 to about 450 V. Keep this in mind when choosing the inverter or the MPPT charge controller, so as not to exceed the maximum input voltage.
04Ventilation matters as much as the module
A module cooled by air flowing underneath runs cooler. PVGIS lets you compare free-standing mounting with building-integrated (poorly ventilated) mounting: the difference is the same in every city.
| City | Free-standing | Integrated | Difference |
|---|---|---|---|
| Rome | 1,484 kWh | 1,423 kWh | −4.1 % |
| Milan | 1,344 kWh | 1,289 kWh | −4.1 % |
| Madrid | 1,610 kWh | 1,540 kWh | −4.3 % |
Yearly output of 1 kWp tilted at 30° facing south. PVGIS 5.3, 14% system losses. With integrated mounting the temperature loss rises from about −8% to about −12%.
4% may not sound like much, but on a 6 kWp system in Rome it is about 370 kWh a year: at €0.25/kWh, about €90 lost every year just to heat.
05What to do in practice
At the same price, prefer TOPCon, back-contact or heterojunction modules with a coefficient around −0.30 %/°C or better. When comparing 400 to 500 W panels, put it next to efficiency.
Leave at least 10 cm of air under the modules and avoid laying them directly on surfaces that get very hot. On a flat roof, tilted frames are already well ventilated.
On light-coloured flat roofs or pergolas, bifacial modules also collect light from the rear, partly offsetting summer losses.
In summer dust and pollen build up. Clean early in the morning with demineralised water, never with cold water on scorching modules.
Do not compare July output with nameplate power: at noon in summer it is normal to see 75-85% of the Wp, even with a perfect system.
06Products to choose well
PV MODULES
Solar panels
Monocrystalline modules in different technologies and power classes: compare temperature coefficient, NOCT and efficiency on the datasheet.
View the panels →COMPLETE KITS
Solar kits
Kits for balconies, homes, campers and cabins, with modules already matched to an inverter or charge controller.
View the kits →CUSTOM
Solar cells
High-efficiency cells for custom modules, where every centimetre and every degree counts.
View the cells →07FAQ and further reading
Can heat break solar panels?
No. Certified modules pass thermal cycling tests between −40 and +85 °C. Heat only reduces power while it is hot: it is a temporary loss, not a fault.
Is it worth cooling panels with water?
Generally not. The gain is a few points and short-lived, while water and limescale leave marks and a strong thermal shock stresses glass and cells.
Do full-black modules get hotter?
They can run slightly hotter, but the difference is small compared with the effect of ventilation and the temperature coefficient.
Does heat shorten module life?
High temperatures slightly accelerate material ageing. Good ventilation helps durability as well as output.
Where do I find the temperature coefficient?
On the datasheet, under "Temperature coefficient of Pmax", in %/°C. Next to it you will find those of Voc and Isc and the NOCT or NMOT value.
Efficiency, dimensions and technologies compared.
Month-by-month output and how much it really covers in summer.
PVGIS data for 1 kWp, typical datasheet coefficients. For a comparison on your project, contact MR WATT.