Digital Voltmeter and Ammeter display lcd red color DC 0-100V 0-50A with Shunt

DISPVA10050-SH

New product

Digital Voltmeter and Ammeter display lcd red color DC 0-100V 0-50A with Shunt

IdeaArticle recommended for measure PV, battery or electronic circuit voltage and current

More details

This product is no longer in stock

By buying this product you can collect up to 1 loyalty point. Your cart will total 1 loyalty point that can be converted into a voucher of 0,05 €.


15,17 €

Data sheet

Height (inches)42 mm
Width158 mm
thickness (mil)84 mm
Weight (Oz)85 g
Operating VoltageDC 4.5 ~ 30V
Measure VoltageDC 0 ~ 100V
Min. resolution (V)0.1 V
Measure Current50A DC (ext shunt required)
Min. resolution (A)0.1 A
Operating Current less than 20 mA
Displaylcd red color
Refresh rateabout 500mS / times
Measuring accuracy1% ( 1 digit)
Operating temperature -10°C to 65°C
Operating humidity10 to 80% (non-condensing)
Operating pressure80 to 106 kPa
EAN0707077343213

More info

Digital Voltmeter and Ammeter display lcd red color DC 0-100V 0-50A with Shunt

Descrizione:

This device allows the measurement of voltage and current, showing on the display the values in volts and amperes due to the shunt, provided with the meter.

SourceWikipedia

In electronics, a shunt is a device which allows electric current to pass around another point in the circuit by creating a low resistance path. The term is also widely used in photovoltaics to describe an unwanted short circuit between the front and back surface contacts of a solar cell, usually caused by wafer damage. The origin of the term is in the verb 'to shunt' meaning to turn away or follow a different path.

An ammeter shunt allows the measurement of current values too large to be directly measured by a particular ammeter. In this case the shunt, a manganin resistor of accurately known resistance, is placed in series with the load, thus all of the current to be measured will flow through it. In order not to disrupt the circuit, the resistance of the shunt is normally very small. The voltage drop across the shunt is proportional to the current flowing through it and since its resistance is known, a voltmeter connected across the shunt can be scaled to directly display the current value.

Shunts are rated by maximum current and voltage drop at that current. For example, a 500 A, 75 mV shunt would have a resistance of 0.15 milliohms, a maximum allowable current of 500 amps and at that current the voltage drop would be 75 millivolts. By convention, most shunts are designed to drop 50 mV, 75 mV or 100 mV when operating at their full rated current and most ammeters consist of a shunt and a voltmeter with full-scale deflections of 50, 75, or 100 mV. All shunts have a derating factor for continuous use, 66% being the most common. Continuous use is a run time of 2+ minutes, at which point the derating factor must be applied. There are thermal limits where a shunt will no longer operate correctly. At 80 °C thermal drift begins to occur, at 120 °C thermal drift is a significant problem where error, depending on the design of the shunt, can be several percent and at 140 °C the manganin alloy becomes permanently damaged due to annealing resulting in the resistance value drifting up or down.

If the current being measured is also at a high voltage potential this voltage will be present in the connecting leads to and in the reading instrument itself. Sometimes, the shunt is inserted in the return leg (groundedside) to avoid this problem. Some alternatives to shunts can provide isolation from the high voltage by not directly connecting the meter to the high voltage circuit. Examples of devices that can provide this isolation are Hall effect current sensors and current transformers (see clamp meters). Current shunts are considered more accurate and cheaper than Hall effect devices. Common accuracy of such devices are ±0.1% & 0.25% and 0.5%.

The Thomas-type double manganin walled shunt and MI type (improved Thomas-type design) were used until the 1990s by NIST and other government labs as the legal reference of an ohm until the advent of thequantum Hall effect. Thomas-type shunts are still used by government and private labs to take very accurate current measurements, as using quantum Hall effect is a time consuming process. The accuracy of these types of shunts is measured in the ppm and sub-ppm scale of drift per year of set resistance.

Wiring: 

  • Black cable (thin): not connected or on voltage regulator - negative 
  • Red cable (thin): Power supply +
  • Black cable (large): COM, to measure
  • Red cable (large): PW+, measuring voltage +
  • Yellow cable (large): IN+, measuring current + 

Connections diagrams:

Voltometro e Amperometro Digitale display led rosso DC 0-100V 0-50A con Shunt Schema 1 collegamento

Voltometro e Amperometro Digitale display led rosso DC 0-100V 0-50A con Shunt Schema 2 collegamento

Voltometro e Amperometro Digitale display led rosso DC 0-100V 0-50A con Shunt Schema 3 collegamento

Idea

Article recommended for measure PV, battery or electronic circuit voltage and current

Idea
  • Voltage between thin red and black cables must be between DC 4.5-30V 
  • The ammeter must be connected in series to power supply negative pole under test load. 
  • When you exceeded 5A for a long time, we recommend to weld connections
  • When black wire is not connected, is better to wrap tape to avoid short circuits
  • If you choose to use such as voltmeter, we recommend that black and yellow wire are connected togheter to avoid ammeter led flash warnings. 